VISCO nhà cung cấp giải pháp NDT chuyên nghiệp

 

Standard Range Fiberscope


OVERVIEW

Standardarized Fiberscopes with Excellent Views

Flexible fiberscopes allow remote visual inspection to be carried out in areas where the route to the area of interest includes negotiating a series of bends or where the length of instrument required is outside the limits of a rigid borescope.
The construction of an Olympus fiberscope is a specialized process, requiring a combination of advanced optical and mechanical technologies, resulting in a finished product with many high performance design features. The standardized fiberscopes achieve the highest image quality in 6.0mm, 8.4mm and 11.3mm diameter at lengths of up to 3.0m (10') with design of four-way angulation and interchangeable optical tip adapters.

Features

Interchangeable optical tip adapters

The focus of the optical system is fixed, however, each inspection has different requirements with regard to depth of field and direction of view. For this reason, all standard model fiberscopes have interchangeable optical tip adaptors to provide versatility and are available in direct or side viewing configuration - just select the tip adaptor most suitable for the application. Separately, a diopter focus compensates for the individual's eyesight.

Image size

The Olympus image size is larger than most other fiberscopes. Due to the optical quality, the image of an Olympus fiberscope can be magnified and maintain a high resolution image.

TF Tube with superior insertability

Most of our fiberscopes employ the patented TF (Tapered Flex) Tube. Ideal for insertion into multiple-bend pipes, the insertion tube flexibility changes continuously-being highly flexible at the tip and rigid at the control section. As a result, these fiberscopes can easily be passed through bends and elbows. At the same time, the gradually increase rigidity of tube as it approaches control section assures easier transmission of publishing/ twisting strength after the first bend. All scopes featuring the TF Tube are marked with the logo shown below.

Four-way angulation

All models feature four-way angulation of the distal end, which aids insertion and maneuverability and helps to 'steer' the tip towards the inspection area.

Photo and video documentation

Video recording and photography are available by connecting a CCD camera or the Olympus digital camera.

Fully waterproof insertion section

Fully waterproof insertion section for underwater use. (Most models) Drip-proof control section.

Four layer insertion tube

The construction of the insertion tube (the part of the instrument inserted into the application area) is especially important to ensure reliability and durability, but without compromising flexibility. Olympus have excelled in this area, creating a design of four individual layers which together protect the internal components and provide fluid resistance.

Four layer insertion tube

SPECIFICATIONS

IF6C5X1/ IF8C5/ IF11C5 Features and Functions
Outer diameter φ6.0mm φ8.4mm φ11.3mm
Effective length 800mm IF6C5X1-8
1,000mm IF8C5-10 IF11C5-10
1,300mm IF6C5X1-13
1,500mm IF8C5-15
2,000mm IF6C5X1-20 IF8C5-20
3,000mm IF6C5X1-30 IF8C5-30 IF11C5-30
Distal end length 13.7mm 21.9mm 25.5mm
Field of view Convertible using optical adapter
Direction of view Direct/ Side viewing (Convertible using optical adapter)
Depth of field (Fixed focus) Convertible using optical adapter
Illumination system Light guide system
Bending section Angulation range Up-Down 120°, Right-Left 100°
Light guide cable length 2,000mm
Industrial Fiberscopes IF6C5X1/ IF8C5/ IF11C5 Optical Adapter Specifications
Scope Optical adapter Field of view Direction of view Depth of field
IF6C5X1 Provided AT60D/FF-IF6C5 60° Direct viewing 11 to ∞mm
Optional AT30D-IF6C5 30° Direct viewing 26 to 372mm
AT60D/NF-IF6C5 60° 5 to 102mm
AT100D-IF6C5 100° 4 to ∞mm
AT30S-IF6C5 30° Side viewing 21 to 138mm
AT60S-NF-IF6C5 60° 4 to 85mm
AT60S/FF-IF6C5 60° 9 to ∞mm
AT100S-IF6C5 100° 4 to ∞mm
IF8C5 Provided AT60D/FF-IF8C5 60° Direct viewing 20 to ∞mm
Optional AT30D/NF-IF8C5 30° Direct viewing 30 to 70mm
AT30D/FF-IF8C5 30° 60 to 250mm
AT60D/NF-IF8C5 60° 9 to 50mm
AT100D/NF-IF8C5 100° 3 to 200mm
AT100D/FF-IF8C5 100° 9 to ∞mm
AT30S-IF8C5 30° Side viewing 45 to 90mm
AT60S/NF-IF8C5 60° 8 to 40mm
AT60S/FF-IF8C5 60° 20 to 240mm
AT100S/NF-IF8C5 100° 3 to 140mm
AT100S/FF-IF8C5 100° 9 to 200mm
IF11C5 Provided AT60D/FF-IF11C5 60° Direct viewing 27 to 390mm
Optional AT30D/NF-IF11C5 30° Direct viewing 38 to 70mm
AT30D/FF-IF11C5 30° 65 to 120mm
AT60D/NF-IF11C5 60° 11 to 45mm
AT100D/NF-IF11C5 100° 5 to 70mm
AT100D/FF-IF11C5 100° 16 to 300mm
AT30S-IF11C5 30° Side viewing 55 to 100mm
AT60S/NF-IF11C5 60° 11 to 40mm
AT60S/FF-IF11C5 60° 28 to 440mm
AT100S/NF-IF11C5 100° 3 to 22mm
AT100S/FF-IF11C5 100° 12 to 250mm
IF6C5X1/ IF8C5/ IF11C5 Operating Environments
IF6C5X1 IF8C5 IF11C5
Operating temperatures Insertion tube In air -10 to 80°C (14 to 176°F)
In water 10 to 30℃ (75 to 86°F)
Other parts than above In air -10 to 50℃ (14 to 122°F)
Operating atmospheric pressure Insertion tube In air / water 1013 to 1317hPa
Other parts than above In air 1013hPa
Liquid resistance
(against machine oil, light oil and 5% saline)
Waterproof Insertion tube
Drip-proof Control section